Hydrosense ONE Ultra Legionella Industrial Kit Refill Pack

£301.94

Availability: 188 in stock

The Hydrosense ONE Ultra Industrial Refill Pack is the perfect solution for ongoing Legionella monitoring with your existing Hydrosense ONE Ultra Industrial Kit. It contains all the replacement consumables required to carry out five additional Legionella tests, so you can continue testing efficiently without needing to purchase a full new kit.

Refill pack contents:
5 × Hydrosense ONE Legionella test strips
5 × buffer syringes
5 × filters
1 × instruction booklet

Please note: This refill pack does not include the reusable components supplied with your original kit – such as the water outlet adaptor and reusable collection bottle. These items are essential for running the tests and are included with the full Hydrosense ONE Ultra Industrial Kit.

Built on Hydrosense’s advanced filtration and rapid detection technology, the refill pack enables on-site Legionella pneumophila sg 1 testing directly from standard water system outlets. It is fully compatible with ½-inch NPT and ¾-inch BPT fittings, when used with the adapter provided in your original kit.

The test detects Legionella pneumophila serogroup 1 by connecting our convenient adaptor to standard plumbing connections (US ½ inch NPT and ¾ inch BPT fittings) and shower hoses.  Our unique Hydrosense filter technology is then attached to the adaptor for water to flow through, trapping any bacteria present.

The test uses Lateral Flow Immunochromatographic Assay (LFICA) technology (same technology used in Covid-19 and pregnancy tests). It isolates the bacteria and distinctly identifies the presence of serogroup 1 (sg1) on a test line with a control line to confirm the test has worked effectively.

This information enables the user to identify the presence of Legionella pneumophila sg1 risk, supporting immediate remedial action. Results are delivered onsite meaning no long waits for lab culture reports.

This test detects Legionella pneumophila sg1 levels of ≥100 CFU/L (0.1 CFU/ml).

VALIDITY OF THE HYDROSENSE ONE ULTRA TEST

HIGH SENSITIVITY AND SPECIFICITY:

The Hydrosense ONE Lateral Flow Test Kit successfully detects Legionella pneumophila serogroup 1 with high sensitivity and specificity, maintaining a high detection level when combined with the filtration kit provided (100 CFU/L for a 250 mL sample).

VERSATILE TEST CONDITIONS:

Displays robustness under varying conditions without compromising results.

NO CROSS-REACTIVITY:

Demonstrates no interference from other common waterborne bacteria or non-pneumophila species of Legionella.

TOLERANCE TO WATER CONDITIONS:

Performs reliably even in hard water and high alkalinity conditions.

HOW THE TEST WORKS

Hydrosense ONE test - negative

If there is only a red line at the C position, sg 1 has not been detected.

Hydrosense ONE test - positive

If red lines are present at both the 1 and C positions, sg 1 has been detected (≥100 CFU/L).

WHICH SECTORS WOULD BENEFIT FROM HYDROSENSE ONE ULTRA LEGIONELLA INDUSTRIAL KIT?

Any industry where humans interact with water poses a risk of Legionella pneumophila infection. Industries that would benefit from regular use of Hydrosense ONE Ultra Legionella Industrial Kit are:

HOSPITALS AND CARE HOMES:

Hospitals and care homes sector

Hospitals, nursing homes, and other healthcare facilities, which typically have complex water systems and treat patients with compromised immune systems, can use Hydrosense ONE for early detection which can lead to fast remediation.

HOTELS, SPAS AND RECREATIONAL:

Hotels, spas and recreational sector

Hotels, resorts, and leisure facilities with aerosol creating water features like showers, pools, spas, and decorative fountains, are a risk for Legionella. Hotels are the number one setting for infection. If Legionella pneumophila is present, it could impact thousands of guests and have extremely excessive cost due to remedial work, closures, cancellations, litigation, and reputational damage.

COMMERCIAL REAL ESTATE:

Commercial real estate sector

Owners and managers of commercial buildings with cooling towers or large water systems would find this technology valuable for monitoring and maintaining the safety of their water systems, prioritising public health, and assisting regulatory compliance.

SHIPPING AND CRUISE LINERS:

Shipping and cruise liner sector

Confined water systems with many cross-contamination opportunities and port-to-ship water transmission can be a serious Legionella risk, putting crew and thousands of passengers in danger of infection. The remote locations make it difficult to get water samples to a lab in good time.

OFFSHORE OPERATIONS:

Offshore sector

Rapid Legionella testing can be particularly useful in remote locations like oil rigs where transporting samples to a distant lab for analysis can be cumbersome, time-consuming, and potentially less accurate if the sample degrades over time.

Weight0.15 kg
Dimensions4 × 19 × 20 cm
Sensitivity:

≥100 CFU/L

Shelf Life:

18 months from date of manufacture

Test Time:

25 minutes

Tests Included:

5

Detects:

Legionella pneumophila serogroup 1

Part Number:

100227

Have you considered?

Shopping Basket
Scroll to Top

Book a demo

Please enter your details and one of our team will be in touch to arrange your demonstration.